| 1 |
SOOW 18/3 |
600 V |
3 copper conductors, 18 AWG |
-40°C to +90°C |
Stranded conductors with thermoset elastomer insulation and jacket |
Flexible and oil resistant |
Light-duty portable tools, control equipment, and temporary power leads |
Small outside diameter and high flexibility for frequent handling |
| 2 |
SOOW 16/3 |
600 V |
3 copper conductors, 16 AWG |
-40°C to +90°C |
Stranded copper conductors with oil-resistant elastomer insulation and jacket |
Flexible and weather resistant |
Portable lighting, small pumps, hand tools, and general service cords |
Useful balance between flexibility and moderate portable-load capability |
| 3 |
SOOW 14/3 |
600 V |
3 copper conductors, 14 AWG |
-40°C to +90°C |
Stranded conductors with oil-resistant, sunlight-resistant elastomer jacket |
General-purpose heavy duty |
Outdoor extension assemblies, construction tools, and portable equipment |
Versatile option for repeated indoor and outdoor movement |
| 4 |
SOOW 12/3 |
600 V |
3 copper conductors, 12 AWG |
-40°C to +90°C |
Stranded copper with thermoset elastomer insulation and outer jacket |
Heavy-duty and abrasion resistant |
Portable pumps, job-site power tools, compressors, and temporary distribution |
Strong choice where mechanical wear and outdoor exposure are expected |
| 5 |
SOOW 10/3 |
600 V |
3 copper conductors, 10 AWG |
-40°C to +90°C |
Stranded copper conductors with oil-resistant elastomer insulation and jacket |
High-load portable service |
Large portable tools, compact motor equipment, generators, and power distribution |
Higher conductor cross-section for demanding portable applications |
| 6 |
SOOW 8/3 |
600 V |
3 copper conductors, 8 AWG |
-40°C to +90°C |
Stranded copper with flexible thermoset elastomer construction |
Robust industrial service |
Portable generators, large motors, industrial power tools, and temporary feeders |
Suitable for higher-power equipment while retaining portable-cable flexibility |
| 7 |
SOOW 6/4 |
600 V |
4 copper conductors, 6 AWG |
-40°C to +90°C |
Three power conductors plus grounding conductor in a flexible elastomer jacket |
Three-phase ready |
Three-phase motors, pumps, mobile equipment, and industrial power connections |
Four-conductor layout supports common three-phase equipment connections |
| 8 |
SOOW 4/4 |
600 V |
4 copper conductors, 4 AWG |
-40°C to +90°C |
Stranded copper conductors with oil-resistant elastomer insulation and jacket |
High mechanical endurance |
Large mobile machinery, industrial motors, heavy pumps, and temporary feeders |
Combines large conductors with a flexible construction for demanding job sites |
| 9 |
SOOW 2/4 |
600 V |
4 copper conductors, 2 AWG |
-40°C to +90°C |
Heavy stranded copper conductors with thermoset elastomer insulation and jacket |
Heavy industrial duty |
Large motor installations, mobile substations, industrial equipment, and feeder assemblies |
Designed for high-current portable power systems requiring four conductors |
| 10 |
SOOW 1/0/4 |
600 V |
4 copper conductors, 1/0 AWG |
-40°C to +90°C |
Large stranded copper conductors with flexible oil-resistant elastomer jacket |
Maximum portable-power capacity |
Large generators, mobile power distribution, mining equipment, and major industrial machinery |
Best suited to high-capacity temporary power where flexibility remains important |